Add to Cart
PID SSR Control 304 Stainless Steel UV Testing Machine 1600 Hours Lifetime Of Lamp
Product Applications:
UV accelerated weathering test chamber simulates damaging effects of long term outdoor exposure of sunlight, heat, moisture on materials and coatings. It exposes specimen to varying conditions of weathering- ultraviolet radiation, moisture and heat to test the performance and improve the quality.
Corresponding standard:
ASTM D4329, D499, D4587, D5208, G154, G53; ISO 4892-3, ISO 11507; EN534; prEN 1062-4, BS 2782; JIS D0205; SAE J2020
Technical Parameter:
Model | KJ-9029 | |
Test chamber size(L×W×H)MM | 1170×450×500 | |
Outside dimension(L×W×H)MM | 1350×540×1480 | |
Chamber materials | 304# stainless steel | |
Temperature range | RT+20℃~70℃ | |
Temperature uniformity: | ±1℃ | |
Temperature fluctuation: | ±0.5℃ | |
Temperature control | PID SSR control | |
Humidity range | ≥90%RH | |
Controller | TEMI 880 programmable controller, touch screen, LCD display | |
Control mode | Balance temperature humidity control (BTHC) | |
Communication function | Be able to control the machine via computer using TEMI control software through RS-232 port on the machine | |
Test cycle setting | Illumination, condensation and water spray test cycle is programmable | |
Distance from specimen to lamp | 50±3mm (adjustable) | |
Center distance between the lamps | 70mm | |
Lamp power & length | 40W/Piece, 1200mm/Piece | |
Lamps amount | 8 pieces of UVA-340 or UVB-313 imported lamps | |
Lifetime of lamp | 1600Hours | |
Irradiance | 1.0W/m2, adjustable directly on TEMI 880 touch screen controller | |
Wavelength of ultraviolet light | UVA is 315-400nm and UVB 280-315nm | |
Effective irradiation area | 900×210mm | |
Irradiation black panel temperature | 50℃~70℃ | |
Standard specimen size | 75×290mm/24 pieces | |
Water depth for water channel | 25mm, automatically control | |
Water consumption | 8L/day, tap water or distilled water | |
Testing time | 0~999H, adjustable | |
Power | 1 phase, 220V/50Hz /±10% 5KW | |
Protection | Overload short circuit protection, over temperature protection, water lacking protection |
Standard accessories:
1. One copy of English user guide.
2. One CD of controller software and operation instruction video.
Kindly note:
1. Please advise whether 8 UVA or 8 UVB lamps are needed when order.
2. UVA-340 lamps can well simulate the natural outdoor exposure. UVB-313 lamps are able to do accelerated test more quickly via stronger irradiation.
Safety protection:
1. Ground fault protection
2. Power overload, short circuit breaker
3. Control circuit overload, short circuit fuse
4. Water lacking protection
5. Over-temperature protection
Usage requirements:
1. Environmental temperature: 5℃~+32℃
2. Environmental humidity: ≤85% 3. Power requirement: AC220(±10%)V/50HZ
4. Capacity: 5KW
5. Fine grounding
Excellent after sale service:
1 YEAR warranty. If you have any problems during testing process, we promise we will give you a reply with 24 hours and solution provide within 3 working days. What you need to do is to send us the controller.
Name | Laboratory Testing Equipment Plastic Rubber Ozone Aging Tester | |||
Model | OC-250 | OC-500 | OC-800 | OC-010 |
Internal dimensions (mm) | 600*600*700 | 700*800*900 | 800*1000*1000 | 1000*1000*1000 |
Overall dimensions (mm) | 960*1150*1860 | 1180*1350*2010 | 1280*1550*2110 | 1500*1550*2110 |
Diameter of holder | 400 mm | 600 mm | 700 mm | 900 mm |
Length of each side | 180 mm | 220 mm | 350 mm | 460 mm |
Temperature range | 0℃~100℃ | |||
Humidity range | 30% - 98%R.H | |||
Temperature fluctuation | ±0.5℃ | |||
Speed rate for cooling: | Ambient~ 0℃ within 20 min. | |||
Ozone concentration: | 1~1000PPHM | |||
Sample holder rotate speed: | 0~10 r/min | |||
Airflow rate | 0 ~ 60L/min | |||
Clamps tensile stretch : | 5%~35% | |||
Power & voltage: | AC380V 50HZ | |||
Standard | ASTM D 1149; IEC60811-403; ISO 1431; JIS K6259; ASTM D1171 |
1. Automatic control and supply ozone gas
2. Equipped with ozone generator
3. Temperature from 0℃ to 100℃
4. Relative humidity from 30%~98%R.H
5. Ozone concentration can be adjusted from 0 to 1000PPHM
6. Dynamic sample holder
Pictures: